--------------------------------------------------------------------- IBM ECA Engineering Change Announcement Parts removed from this machine and returned to IBM must be genuine, unaltered IBM Parts IBM World Trade Corporation, CE Department Germany --------------------------------------------------------------------- EC NUMBER : ECC27232 DATE : 90-01-11 MANDATORY : N AUTOMATIC SHIPMENT: N SERVICE CODE : 33 PARTS SOURCE : FUJI AVAILABILITY DATE: 89/12 PURPOSE: THIS ECA IS RELEASED FOR JAPAN USE ONLY TO FIX SYSTEM HUNG UP CAUSED BY ERRATA OF KEYBOARD MPU DURING MOUSE OPERATION. THIS PROBLEM MAYBE OCCUR HIGH INTERMITTENTLY ON SMART/MICRO CADAM APPLICATION S/W. Type Machines Affected Mod. With and/or Feature/Device B/M to be Serv Syst Stg. B/M Description Installed Hour Hour Plant 97 S0A B/M0005571 9700001 THRU 9701200 B/M57F0083 00.5 00.5 T0A/ TRA B/M0005571 9710001 THRU 9716113 B/M57F0083 00.5 00.5 T0B/ TRB B/M0005571 9730001 THRU 9734765 B/M57F0083 00.5 00.5 TOC/ TRC B/M0005571 9750001 THRU 9751120 B/M57F0083 00.5 00.5 V0B B/M0005571 9770001 THRU 9771188 B/M57F0083 00.5 00.5 V0C B/M0005571 9780001 THRU 9780405 B/M57F0083 00.5 00.5 PHYSICAL CHECK: CHECK KEYBOARD MPU ON SYSTEM BOARD IF I8742(P/N 72X8455) IS USED, APPLY THIS FBM. FOR KEYBOARD MPU LOCATION,REFER TO FBM INSTALLATION INSTRUCTION. PREREQUISITES: NONE COMPANION: NONE CONCURRENT: NONE DETAIL: CHANGE KEYBOARD MPU ON SYSTEM BOARD FROM I8742(P/N 72X8455) TO I8042AH(P/N 90X9052). NOTES: THE FBM IS AVAILABLE FOR ONE YEAR. ---------------------------------------------------------------------