--------------------------------------------------------------------- IBM ECA Engineering Change Announcement Parts removed from this machine and returned to IBM must be genuine, unaltered IBM Parts IBM World Trade Corporation, CE Department Germany --------------------------------------------------------------------- EC NUMBER : ECD22610 DATE : 93-06-17 MANDATORY : N AUTOMATIC SHIPMENT: N SERVICE CODE : 33 PARTS SOURCE : YASU AVAILABILITY DATE: 93/05 PURPOSE: To solve hung-up problems which may occur when Bus Master Adapter is installed in the PS/55 Model 5551-S Stage 1,and this field EC was revised from EC# C27278 FBM# 64F8690. The following adapters have Bus Master Function. -Micro Channel SCSI Adapter/A (16Bit,32Bit) -Inteligent Communication Adapter/A Portmaster -Numeric Processing Adapter -Japanese Voice Adapter/A -80MB HDD attached SCSI Adapter/A -Token Ring 16/4 Bus-master 32 Adapter/A Type Machines Affected Mod. With and/or Feature/Device B/M to be Serv Syst Stg. B/M Description Installed Hour Hour Plant 98 5551- B/M0005551 S/N RANGE B/M64F8690 00.5 00.5 S09 9700001-->9719300 PHYSICAL CHECK: Check the System Board P/N and EC#. When the Bus Master Adapter is installed in the 5551-S Stage 1, if the System Board is P/N 94X5577 or 38F9039,install this FBM. PREREQUISITES: NONE COMPANION: NONE CONCURRENT: NONE DETAIL: Replace the System Board with P/N 56F7422. NOTES: Return the removed System Board with EC completion report to stock center as soon as possible after EC installation. ---------------------------------------------------------------------