    Title

    IBM SCSI-2 Fast/Wide Adapter/A, IBM SCSI-2 Differential Fast/Wide Adapter/A, IBM 2GB SCSI-2 Fast/Wide Disk Drive

    Abstract

    The IBM SCSI-2 Fast/Wide Adapter/A is a dual ported fast and wide (two bytes wide) SCSI-2 Micro Channel adapter that provides synchronous SCSI bus data rates of up to 20 megabytes per second for attachment of SCSI disks, CD-ROMs, tape devices, read/write optical devices and storage subsystems on many of the RISC System 6000/(TM) family of processors. The internal and external port are each capable of addressing up to seven single ended (SE) SCSI devices providing a maximum of 14 devices per adapter. The number of physical devices attached to each port is limited by SCSI bus cabling restrictions. (See the Limitations section of this Announcement for these restrictions.)

    The IBM SCSI-2 Differential Fast/Wide Adapter/A is a dual ported fast and wide (two bytes wide) SCSI Micro Channel adapter that provides synchronous SCSI bus data rates of up to 20 megabytes per second for attachment of Differential SCSI disks, disk subsystems, tape devices and read/write optical subsystems on many of the RISC System/6000(TM) family of processors. The internal single ended (SE) port is capable of addressing up to seven single ended (SE) SCSI devices and the differential external port is capable of addressing up to seven differential SCSI devices providing a maximum of 14 devices per adapter. The number of physical devices attached to each port is limited by SCSI bus cabling restrictions. The external differential port has the capability of supporting a total cable length of 25 meters (82 feet).

    Additional system, subsystem and high availability connections are also now available with the differential system-to-system and Y-cable features.

    The 2GB SCSI-2 Fast/Wide Disk Drive is a 2GB disk drive for attachment to the SCSI-2 Fast/Wide Adapter/A and cables which feature a 16-bit interface. (TM) Trademark of International Business Machines Corporation


    General Availability

    Planned General Availability Date is June 10, 1994.


    Product Number

     Description             Machine         Model          Feature
                              Type
     --------------------    --------   ----------------    -------
    IBM RISC System/6000      7006      41W,41T
    IBM RISC System/6000      7009      C10
    IBM RISC System/6000      7011      250,25E,25S,25T,
                                        25W
    IBM RISC System/6000      7012      32E,32H,340,34H,
                                        350,355,360,365,
                                        370,375,37T,
                                        380,390
    IBM RISC System/6000      7013      52H,53E,53H,550,
                                        55E,55S,55L,560,
                                        56F,570,57F,580,
                                        58F,58H,590,59H
    IBM RISC System/6000      7015      950,95E,970,97B,
                                        97E,97F,980,98B,
                                        98E,98F,990,99E,
                                        99F,99J,99K,
                                        R10,R20,R24
    IBM RISC System/6000      7030      3AT,3BT
    -IBM SCSI-2 Fast/Wide Adapter/A                           2415
    -IBM SCSI-2 Differential Fast/Wide
      Adapter/A                                               2416
    -.6M SCSI-2 16-bit Differential Wide
      System to System Cable                                  2424
    -2.5M SCSI-2 16-bit Differential
      Fast/Wide System to System Cable                        2425
    -16-bit Y-Cable for IBM SCSI-2
      Differential Fast/Wide
      Adapter/A                                               2426
    -8-bit Y-Cable for IBM SCSI-2
      Differential Fast/Wide
      Adapter/A                                               2427
    -16-bit IBM SCSI-2 Fast/Wide Adapter/A
      to Dual Ported Device Cable                             2435
    -16-bit IBM SCSI-2 Differential Fast/Wide
      Adapter/A to Dual Ported Device Cable                   2436
    -8-bit IBM SCSI-2 Fast/Wide Adapter/A
      to Dual Ported Device Cable                             2437
    -8-bit IBM SCSI-2 Differential Fast/Wide
      Adapter/A to Dual Ported Device Cable                   2438
    -8-bit IBM SCSI-2 Fast/Wide Adapter/A
      to Single Ported Device Cable                           2439
     
    
    IBM RISC System/6000      7006      41W,41T
    IBM RISC System/6000      7009      C10
    IBM RISC System/6000      7012      380,390
    IBM RISC System/6000      7030      3AT,3BT
    -2GB SCSI-2 Fast/Wide Disk Drive                          2586
    IBM RISC System/6000      7006      41W,41T
    IBM RISC System/6000      7009      C10
    IBM RISC System/6000      7030      3AT,3BT
    -2GB SCSI-2 Fast/Wide Disk Drive(Select)*                 2588
     
    IBM RISC System/6000      7013      58H,590
    -IBM SCSI-2 Differential Fast/Wide
      Adapter/A (Select)*                                     2413
    -IBM SCSI-2 Fast/Wide Adapter/A(Select)*                  2414
    -8-bit Internal 6-Drop Cable for
      SCSI-2 Fast/Wide Adapters (Select)*                     2428
    -16-bit Internal 6-Drop Cable for
      SCSI-2 Fast/Wide Adapters (Select)*                     2429
    -8-bit Internal 6-Drop Cable for
      SCSI-2 Fast/Wide Adapters                               2430
    -16-bit Internal 6-Drop Cable for
      SCSI-2 Fast/Wide Adapters                               2431
    -2GB SCSI-2 Fast/Wide Disk Drive                          2586
    -2GB SCSI-2 Fast/Wide Disk Drive(Select)*                 2588
     
    IBM RISC System/6000      7013      59H
    -IBM SCSI-2 Differential Fast/Wide
      Adapter/A(Select)*                                      2417
    -8-bit Internal 6-Drop Cable for
      SCSI-2 Fast/Wide Adapters                               2430
    -16-bit Internal 6-Drop Cable for
      SCSI-2 Fast/Wide Adapters                               2431
    -16-bit Internal 6-Drop Cable for IBM SCSI-2
      Fast/Wide Adapters(Select)*                             2433
    -2GB SCSI-2 Fast/Wide Disk Drive                          2586
    -2GB SCSI-2 Fast/Wide Disk Drive(Select)*                 2587
     
    IBM RISC System/6000      7015      97B,98B,990
    -IBM SCSI-2 Differential Fast/Wide
      Adapter/A(Select)*                                      2413
    -IBM SCSI-2 Fast/Wide Adapter/A(Select)*                  2414
     
    IBM RISC System/6000      7015      R24
    -2GB SCSI-2 Fast/Wide Disk Drive                          2586
    
    Scalable POWERparallel    9076      201,202,203
    Systems                             301,302,303
                                        401,402,403
    -IBM SCSI-2 Differential Fast/Wide
      Adapter/A                                               2416
     
    *  These Selects/Features are only available on the initial
       Plant order.  They are not available via MES or field
       installable.
    

    Highlights


    Description

    IBM SCSI-2 Fast/Wide Adapter/A

    IBM SCSI-2 Differential Fast/Wide Adapter/A

    GROWTH ENABLEMENT - Connectivity Improvement:

    IBM SCSI-2 Fast/Wide Adapter/A (FC#2415)

    The IBM SCSI-2 Fast/Wide Adapter/A is a dual ported fast (10 Mhz) and wide (2 bytes wide) SCSI-2 Micro Channel Adapter that can provide synchronous SCSI bus data rates of up to 20 megabytes per second. It provides high performance attachment to single ended (SE) SCSI disks, CD-ROMs, tape devices, read/write (R/W) optical devices and storage subsystems. The maximum data rate is dependent on the maximum data rate of the devices.

    The IBM SCSI-2 Fast/Wide Adapter/A has one usable internal SE port and one external SE port. Each SE port is capable of addressing up to seven SE SCSI devices. The number of physical devices attached to each port is limited by SCSI bus cabling restrictions. (See the Limitations section of this Announcement for these restrictions.) The internal port of this adapter supports either 8-bit or 16-bit devices via a 8-bit or 16-bit connector. Only one of these two connectors may be used at one time. (Devices of different bus attachment widths cannot be connected/used at the same time.) External cabling may be up to 6 meters (19.6 feet) when attached to the IBM 9334-010 or 9334-500, 3 meters when attached to anything else and is supplied by the attaching device.

    Characteristics:

    IBM SCSI-2 Differential Fast/Wide Adapter/A (FC#2416)

    The IBM SCSI-2 Differential Fast/Wide Adapter/A is a dual ported fast (10 Mhz) and wide (2 bytes wide) SCSI-2 Micro Channel Adapter that can provide synchronous SCSI bus data rates of up to 20 megabytes per second. The SCSI-2 Differential Fast/Wide Adapter/A provides high performance attachment to Differential SCSI disks, disk subsytems, tape devices and read/write optical subsystems. The maximum data rate is dependent on the maximum data rate of the device. The IBM SCSI-2 Differential Fast/Wide Adapter/A has one usable internal single ended port and one external Differential port. The internal port is capable of addressing up to seven single ended devices, the external port is capable of addressing up to seven differential devices. The number of physical devices attached to each port is limited by SCSI bus cabling restrictions. (See the Limitations section of this Announcement for these restrictions.) The internal port of this adapter supports either 8-bit or 16-bit devices via a 8-bit or 16-bit connector. Only one of these two connectors may be used at one time. (Devices of different bus attachment widths cannot be connected/used at the same time.) The external Differential SCSI bus is capable of supporting cable lengths of 25 meters (82 feet).

    Additional system, subsystem and high availability connections are also now available with the differential system-to-system and Y-cable features.

    Characteristics:

    IBM SCSI-2 Differential Fast/Wide Adapter/A (Select) (#2413)

    (Model 58H and 590) The SCSI-2 Differential Fast/Wide Adapter/A (Select) replaces the standard SCSI-2 adapter on the initial plant order. This feature will require installation in slot 8 of the Micro Channel. This feature is only available on the initial plant order.

    IBM SCSI-2 Fast/Wide Adapter/A (Select) (#2414)

    (Model 58H and 590) The SCSI-2 Fast/Wide Adapter/A (Select) replaces the standard SCSI-2 adapter on the initial plant order. This feature will require installation in slot 8 of the Micro Channel. This feature is only available on the initial plant order. .6m 16-bit SCSI-2 Differential System to System Cable (#2424)
    The .6m 16-bit SCSI-2 Differential System to System Cable provides for the connection between two or more RISC System/6000 processors that each have a SCSI-2 Differential Fast/Wide Adapter/A (#2416) and a SCSI-2 Differential Fast/Wide Y-Cable (#2426) (16-bit) This 68-pin cable is .6 meter (22.7 inches) in length.

    2.5m 16-bit SCSI-2 Differential System to System Cable (#2425)

    This cable provides for the connection between two or more RISC System/6000 processors that each have a SCSI-2 Differential Fast/Wide Adapter/A (#2416) and a SCSI-2 Differential Fast/Wide Y-Cable (#2426) (16-bit) installed. This 68-pin cable is 2.5 meter (8.2 feet) in length.

    16-bit Y-Cable for IBM SCSI-2 Differential
    Fast/Wide Adapter/A (#2426)
    This Y-Cable provides attachment and termination of an IBM 16-bit SCSI-2 Differential device/subsystem to two separate RISC System/6000 systems which each have a SCSI-2 Differential Fast/Wide Adapter/A (#2416) installed. This is particularly desirable in increased availability environments. Each system will require a Y-cable. The Y-cable will be attached to the cabling that comes with the 16-bit SCSI-2 Differential device/subsystem. A SCSI-2 Differential Terminator is included. The Y-cable is .940 meter (37 inches) in length.

    8-bit Y-Cable for IBM SCSI-2 Differential
    Fast/Wide Adapter/A (#2427)
    This Y-Cable provides attachment and termination of an IBM 8-bit SCSI-2 differential device/subsystem to two separate RISC System/6000 systems which each have a SCSI-2 Fast/Wide Differential Adapter/A (#2416) installed. This is particularly desirable in increased availability environments. Each system will require a Y-cable. The Y-cable will be attached to the cabling that comes with the 8-bit SCSI-2 Differential device/subsystem. A SCSI-2 Differential Terminator is included. The Y-cable is .765 meter (30 inches) in length.

    8-bit Internal 6-Drop Cable for IBM SCSI-2
    Fast/Wide Adapters (Select) (#2428)

    (Model 58H and 590) This cable replaces the standard internal cable on the initial plant order when the SCSI-2 Differential Fast/Wide Adapter/A (Select) (#2413) or the SCSI-2 Fast/Wide Adapter/A (Select) (#2414) is ordered. This feature is only available on the initial plant order.

    16-bit Internal 6-Drop Cable for IBM SCSI-2
    Fast/Wide Adapters (Select) (#2429)

    (Model 58H and 590) This cable replaces the standard internal cable on the initial plant order when the SCSI-2 Differential Fast/Wide Adapter/A (Select) (#2413) or the SCSI-2 Fast/Wide Adapter/A (Select) (#2414) is ordered. This feature is only available on the initial plant order.

    8-bit Internal 6-Drop Cable for IBM SCSI-2
    Fast/Wide Adapters (#2430)

    (Model 58H, 590 and 59H) This cable is used in conjunction with the SCSI-2 Fast/Wide Adapter/A (#2415) or the SCSI-2 Differential Fast/Wide Adapter/A (#2416). This cable provides connection to up to six internal I/O devices to the 8-bit port connector. (Maximum of two internal cables, all types)

    16-bit Internal 6-Drop Cable for IBM SCSI-2
    Fast/Wide Adapters (#2431)

    (Model 58H, 590 and 59H) The 16-bit Internal 6-Drop Cable for IBM SCSI-2 Fast/Wide Adapters is used in conjunction with the SCSI-2 Fast/Wide Adapter/A (#2415) or the SCSI-2 Differential Fast/Wide Adapter/A (#2416). This cable provides connection to up to six internal I/O devices to the 16-bit port connector. (Maximum of two internal cables, all types)

    16-bit Internal 6-Drop Cable for IBM SCSI-2
    Fast/Wide Adapters Select (#2433)

    (Model 59H) The 16-bit Internal 6-Drop Cable for IBM SCSI-2 Fast/Wide Adapters Select replaces the standard 8-bit internal 6-Drop cable on the initial plant order. This feature is only available on the initial plant order.

    16-bit IBM SCSI-2 Fast/Wide Adapter/A to Dual Ported Device
    Cable (#2435)

    The 16-bit IBM SCSI-2 Fast/Wide Adapter/A to Dual Ported Device Cable provides attachment from the IBM SCSI-2 Fast/Wide Adapter/A (#2414, #2415, #9216) to the first 16-bit single ended dual ported device on the SCSI bus. The cable is 1.5 meter (59 inches) in length.

    16-bit IBM SCSI-2 Differential Fast/Wide Adapter/A to Dual Ported
    Device Cable (#2436)

    The 16-bit IBM SCSI-2 Differential Fast/Wide Adapter/A to Dual Ported Device Cable provides attachment from the IBM SCSI-2 Differential Fast/Wide Adapter/A (#2413, #2416, #2417) to the first 16-bit differential dual ported device on the SCSI bus. The cable is 1.5 meter (59 inches) in length.

    8-bit IBM SCSI-2 Fast/Wide Adapter/A to Dual Ported Device
    Cable (#2437)

    The 8-bit IBM SCSI-2 Fast/Wide Adapter/A to Dual Ported Device Cable provides attachment from the IBM SCSI-2 Fast/Wide Adapter/A (#2414, #2415, #9216) to the first 8-bit single ended dual ported device on the SCSI bus. The cable is 1.5 meter (59 inches) in length.

    8-bit IBM SCSI-2 Differential Fast/Wide Adapter/A to Dual
    Ported Device Cable (#2438)

    The 8-bit IBM SCSI-2 Differential Fast/Wide Adapter/A to Dual Ported Device Cable provides attachment from the IBM SCSI-2 Differential Fast/Wide Adapter/A (#2413, #2416, #2417) to the first 8-bit differential dual ported device on the SCSI bus. The cable is 1.5 meter (59 inches) in length.

    8-bit IBM SCSI-2 Fast/Wide Adapter/A to Single Ported Device
    Cable (#2439)

    The 8-bit IBM SCSI-2 Fast/Wide Adapter/A to single Ported Device Cable provides attachment from the IBM SCSI-2 Fast/Wide Adapter/A (#2414, #2415, #9216) to the first 8-bit single ended single ported device on the SCSI bus. The cable is 1.5 meter (59 inches) in length.

    2GB SCSI-2 Fast/Wide Disk Drive (#2586)

    This is a 2GB SCSI-2 disk drive for attachment to the SCSI-2 Fast/Wide Adapter/A and cables which feature a 16-bit interface.

    Characteristics:

    2GB SCSI-2 Fast/Wide Disk Drive(Select) (#2587) (Model 59H)

    and

    2GB SCSI-2 Fast/Wide Disk Drive(Select) (#2588) (Not on Model
    380 and 390)

    This feature replaces the standard disk drive with the 2GB SCSI-2 Fast/Wide Disk Drive on the initial plant order.


    Product Positioning

    These SCSI-2 Fast/Wide Adapters are IBM's high performance SCSI connections to the wide range of RISC System/6000 storage devices and subsystems, and conform to the latest SCSI standard used in the open systems marketplace. By contrast with the previous SCSI-1 and SCSI-2 Controllers and Adapters for the RISC System/6000, they offer:
    - Double the maximum synchronous data transfer rate, from 10 MBps to 20 MBps
    - Greater flexibility in physical planning due to the increased SCSI cable lengths possible with the Differential adapter
    - Double the number of devices, from 7 to 14. These new adapters also offer upward compatibility with existing IBM devices. As before, however, note that single-ended SCSI devices and controllers cannot be mixed with differential SCSI devices and controllers on the same SCSI bus. Since these adapters provide this new capability at the same price as the predecessor SCSI-2 and SCSI-1 adapters, new and current RISC System/6000 customers should choose the new SCSI-2 Fast/Wide Adapters rather than the older products when selecting a new SCSI controller. There may be some isolated exceptions, noted in the Limitations section.

    @


    Publications

    There are no new publications shipped with the announced product. Current product publications will be revised.

    Technical Information

    Specified Operating Environment

    Machine Requirements

    Limitations

    IPL capability with the #2413, #2414, #2415 and #2416 adapters is supported only on the following:

               Machine Type        Model
               ------------       -------
                 7006               41T
                 7006               41W
                 7009               C10
                 7011               250
                 7011               25E
                 7011               25S
                 7011               25T
                 7011               25W
                 7012               380
                 7012               390
                 7013               590
                 7013               58H
                 7013               59H
                 7015               990
                 7015               99E
                 7015               99F
                 7015               99J
                 7015               99K
                 7015               R20
                 7015               R24
                 7030               3AT
                 7030               3BT
    
    Cable length restrictions

    The maximum length guideline for SCSI fast operation is typically three meters unless specialized cableing and termination are utilized as in the case for the IBM SCSI-2 Controller implementations. These tuned configurations extend operation of IBM-supported devices up to six meters, provided that IBM-supported cables and terminators are used.

    Additional information about cable length restrictions can be found in the document ANSI Doc X3T9.2/86 rev 10h.

    Programming Requirements

    The IBM SCSI-2 Fast/Wide Adapter/A and IBM SCSI-2 Differential Fast/Wide Adapter/A require updates from the initial release of AIX 3.2.5. Customers ordering systems with AIX 3.2.5 will receive these updates on the system or media. Customers ordering hardware separately must ensure access to the latest update of AIX 3.2.5. See Programming Announcement ZP940264 (RFA 22727) dated May 24, 1994 for more information.


    Planning Information

    Cable Orders

    Please contact your IBM representative for the unique cable requirements of the products in this announcement.

    Security, Auditability and Control

    User management is responsible for evaluation, selection and implementation of security features, administrative procedures and appropriate controls in application systems and communications facilities.

    Charges

    Consult your IBM Marketing Representative.


    Terms and Conditions

    All Terms and Conditions are the same as those which apply to the IBM 70XX/RISC System/6000.


    Announcement Countries

    All European, Middle Eastern and African Countries.