AdapterID 06205h AdapterName "Excelan EXOS 215T Intelligent Ethernet Adapter" NumBytes 2 NamedItem Prompt "Memory Size" Choice "512K bytes" pos[1]=XXXXXXX0b Choice "1024K bytes" pos[1]=XXXXXXX1b Help "Select the amount of RAM that is installed on your EXOS 215T adapter." NamedItem Prompt "Memory Base" Choice "C0000 Hex" pos[1]=000XXXXXb mem 0c0000h-0c3fffh Choice "C4000 Hex" pos[1]=001XXXXXb mem 0c4000h-0c7fffh Choice "C8000 Hex" pos[1]=010XXXXXb mem 0c8000h-0cbfffh Choice "CC000 Hex" pos[1]=011XXXXXb mem 0cc000h-0cffffh Choice "D0000 Hex" pos[1]=100XXXXXb mem 0d0000h-0d3fffh Choice "D4000 Hex" pos[1]=101XXXXXb mem 0d4000h-0d7fffh Choice "D8000 Hex" pos[1]=110XXXXXb mem 0d8000h-0dbfffh Choice "DC000 Hex" pos[1]=111XXXXXb mem 0dc000h-0dffffh Help "Select the base address of the 16-Kbyte window in host memory space to which the EXOS 215T will be mapped. Conflicting assignments are marked with an asterisk and must be changed. Under normal circumstances select ." NamedItem Prompt "I/O Base" Choice "310 Hex" pos[0]=XXX10XXXb io 310h-317h Choice "308 Hex" pos[0]=XXX01XXXb io 308h-30fh Choice "300 Hex" pos[0]=XXX00XXXb io 300h-307h Help "Select the base address of an 8-byte block of addresses in host I/O space to be used by the EXOS 215T. Conflicting assignments are marked with an asterisk and must be changed. Under normal circumstances select <310>." NamedItem Prompt "Interrupt Level" Choice "IRQ 5" pos[0]=110XXXXXb int 5 Choice "IRQ 9" pos[0]=000XXXXXb int 9 Choice "IRQ 10" pos[0]=001XXXXXb int 10 Choice "IRQ 11" pos[0]=010XXXXXb int 11 Choice "IRQ 12" pos[0]=011XXXXXb int 12 Choice "IRQ 14" pos[0]=100XXXXXb int 14 Choice "IRQ 15" pos[0]=101XXXXXb int 15 Choice "No Interrupt" pos[0]=111XXXXXb Help "Select the interrupt level to be used by the EXOS 215T when interrupting the host. Under normal circumstances select ." NamedItem Prompt "SQE Test (Heartbeat check)" Choice "Enabled" pos[0]=XXXXXX1Xb Choice "Disabled" pos[0]=XXXXXX0Xb Help "Signal Quality Error (SQE) test may either be enabled or disabled. To operate with an Ethernet version 1.0 transceiver SQE test must be disabled; otherwise, it should normally be enabled." NamedItem Prompt "CRS Error Detection" Choice "Disabled" pos[0]=XXXXX0XXb Choice "Enabled" pos[0]=XXXXX1XXb Help "Detection of Carrier Sense (CRS) errors may either be enabled or disabled; when disabled, carrier sense errors will be ignored. To operate with a broadband transceiver, CRS error detection should be disabled; otherwise, it should normally be enabled." NamedItem Prompt "PROM Size and Memory Base" Choice "Not Installed" pos[1]=XXX1111Xb Choice "32K PROM - C0000 Hex" pos[1]=XXX0001Xb mem 0c0000h-0c7fffh Choice "32K PROM - C8000 Hex" pos[1]=XXX0011Xb mem 0c8000h-0cffffh Choice "32K PROM - D0000 Hex" pos[1]=XXX0101Xb mem 0d0000h-0d7fffh Choice "32K PROM - D8000 Hex" pos[1]=XXX0111Xb mem 0d8000h-0dffffh Choice "16K PROM - C0000 Hex" pos[1]=XXX0000Xb mem 0c0000h-0c3fffh Choice "16K PROM - C4000 Hex" pos[1]=XXX0010Xb mem 0c4000h-0c7fffh Choice "16K PROM - C8000 Hex" pos[1]=XXX0100Xb mem 0c8000h-0cbfffh Choice "16K PROM - CC000 Hex" pos[1]=XXX0110Xb mem 0cc000h-0cffffh Choice "16K PROM - D0000 Hex" pos[1]=XXX1000Xb mem 0d0000h-0d3fffh Choice "16K PROM - D4000 Hex" pos[1]=XXX1010Xb mem 0d4000h-0d7fffh Choice "16K PROM - D8000 Hex" pos[1]=XXX1100Xb mem 0d8000h-0dbfffh Choice "16K PROM - DC000 Hex" pos[1]=XXX1110Xb mem 0dc000h-0dffffh Help "Select the base address of the 16- or 32-Kbyte window in host memory space to which the PROM will be mapped. Conflicting assignments are marked with an asterisk and must be changed. If your EXOS 215T does not have a PROM installed (normal case) select ."